You are here

Hydraulic testers | Webtec

Enter maximum flow to measure
Image
Flow range
Pressure range
Temperature range
Generates report
Reading
Fluid
Article number
Stock
Custom text
Hydraulic tester
Flow range
20-800 Lpm (± 1%)
Pressure range
0-480 bar (± 2,4)
Temperature range
0-120°C (± 1)
Generates report
Yes, with QuickCert app
Reading
Digital display
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
DHM804S7L

Stock/Dispatch
1
Please ask
Hydraulic tester
Flow range
20-800 Lpm (± 8)
Pressure range
0-480 bar (± 7,7)
Temperature range
0-120°C (± 1)
Generates report
No
Reading
Digital and dial indicator
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
DHT801S7L

Stock/Dispatch
1
Immediate
Hydraulic tester
Flow range
10-400 Lpm (± 1%)
Pressure range
0-420 bar (± 2,1)
Temperature range
0-120°C (± 1)
Generates report
Yes, with QuickCert app
Reading
Digital display
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
DHM404B6

Stock/Dispatch
1
Immediate
Hydraulic tester
Flow range
10-400 Lpm (± 4)
Pressure range
0-420 bar (± 6,7)
Temperature range
-10 +125°C (± 1)
Generates report
No
Reading
Digital and dial indicator
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
DHT04B

Stock/Dispatch
1
Immediate
Hydraulic tester
Flow range
10-270 Lpm (± 10,8)
Pressure range
0-420 bar (± 6,7)
Temperature range
20-80°C (± 2,5)
Generates report
No
Reading
Dial indicator
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
RFIK270B6

Stock/Dispatch
1
Immediate
Hydraulic tester
Flow range
8-300 Lpm (± 3)
Pressure range
0-420 bar (± 6,7)
Temperature range
-10 +125°C (± 1)
Generates report
No
Reading
Digital and dial indicator
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
DHT03B

Stock/Dispatch
0
Please ask
Hydraulic tester
Flow range
10-200 Lpm (± 8)
Pressure range
0-420 bar (± 6,7)
Temperature range
20-80°C (± 2,5)
Generates report
No
Reading
Dial indicator
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
RFIK200B6

Stock/Dispatch
0
Please ask
Hydraulic tester
Flow range
10-120 Lpm (± 4,8)
Pressure range
0-420 bar (± 6,7)
Temperature range
20-80°C (± 2,5)
Generates report
No
Reading
Dial indicator
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
RFIK120B6

Stock/Dispatch
0
Please ask
Hydraulic tester
Flow range
5-60 Lpm (± 2,4)
Pressure range
0-420 bar (± 6,7)
Temperature range
20-80°C (± 2,5)
Generates report
No
Reading
Dial indicator
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
RFIK060B6

Stock/Dispatch
0
Please ask
Hydraulic tester
Flow range
2-30 Lpm (± 1,2)
Pressure range
0-420 bar (± 6,7)
Temperature range
20-80°C (± 2,5)
Generates report
No
Reading
Dial indicator
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
RFIK030B6

Stock/Dispatch
0
Please ask
Hydraulic tester
Flow range
5-210 Gpm (± 2,1)
Pressure range
0-7000 psi (± 112)
Temperature range
14-257°F (± 2)
Generates report
No
Reading
Digital and dial indicator
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
DHT08S

Stock/Dispatch
0
Please ask
Hydraulic tester
Flow range
5-210 Gpm (± 1%)
Pressure range
0-7000 psi (± 35)
Temperature range
32-250°F (± 2)
Generates report
Yes, with QuickCert app
Reading
Digital display
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
DHM804S7

Stock/Dispatch
0
Please ask
Hydraulic tester
Flow range
2.5-105 Gpm (± 1)
Pressure range
0-6000 psi (± 96)
Temperature range
14-257°F (± 2)
Generates report
No
Reading
Digital and dial indicator
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
DHT04S

Stock/Dispatch
0
Please ask
Hydraulic tester
Flow range
2,5-100 Gpm (± 1%)
Pressure range
0-6000 psi (± 30)
Temperature range
32-250°F (± 2)
Generates report
Yes, with QuickCert app
Reading
Digital display
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
DHM404S6

Stock/Dispatch
0
Please ask
Hydraulic tester
Flow range
2-80 Gpm (± 0,8)
Pressure range
0-6000 psi (± 96)
Temperature range
14-257°F (± 2)
Generates report
No
Reading
Digital and dial indicator
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
DHT03S

Stock/Dispatch
0
Please ask
Hydraulic tester
Flow range
5-70 Gpm (± 2,8)
Pressure range
0-6000 psi (± 96)
Temperature range
68-176°F (± 5)
Generates report
No
Reading
Dial indicator
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
RFIK270S6

Stock/Dispatch
0
Please ask
Hydraulic tester
Flow range
4-54 Gpm (± 2,16)
Pressure range
0-6000 psi (± 96)
Temperature range
68-176°F (± 5)
Generates report
No
Reading
Dial indicator
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
RFIK200S6

Stock/Dispatch
0
Please ask
Hydraulic tester
Flow range
4-32 Gpm (± 1,28)
Pressure range
0-6000 psi (± 96)
Temperature range
68-176°F (± 5)
Generates report
No
Reading
Dial indicator
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
RFIK120S6

Stock/Dispatch
0
Please ask
Hydraulic tester
Flow range
1-16 Gpm (± 0,64)
Pressure range
0-6000 psi (± 96)
Temperature range
68-176°F (± 5)
Generates report
No
Reading
Dial indicator
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
RFIK060S6

Stock/Dispatch
0
Please ask
Hydraulic tester
Flow range
0,5-8 Gpm (± 0,32)
Pressure range
0-6000 psi (± 96)
Temperature range
68-176°F (± 5)
Generates report
No
Reading
Dial indicator
Fluid
Hydraulic oils
Brand - Article No

Hydraulic tester
WEBTEC
RFIK030S6

Stock/Dispatch
0
Please ask